Sodium Carboxymethyl Cellulose (CMC) Viscosity Testing Method
Sodium Carboxymethyl Cellulose (CMC) Viscosity Testing Method
Accurately weigh 2.4g Sodium Carboxymethyl Cellulose sample (accurate to 0.001g), add 237.6ml distilled water into glass. Disperse the Sodium Carboxymethyl Cellulose sample by a high-speed impeller mill, discontinuously stir to make the sample fully dissolute evenly. Lay for 3 hours. Put it into thermostat water bath with the temperature 25±0.5℃ and keep constant temperature for 30 minutes. Take out. And then determine its absolute viscosity by Brookfield viscometer (DV-II+ type), spindle # 4 (spindle can be replaced according to viscosity), speed 30 rpm.